Rating (Input: Natural and L.P. Gas) 0-4500ft elevation
Input (BTU/ Hr) | |||
Model
|
Min
|
Max
|
Length
|
PH-40 | 20,000 | 40,000 | 10′ |
PH-50 | 25,000 | 50,000 | 15′ |
PH-75 | 37,000 | 75,000 | 20′ |
PH-40 (High output) | 20,000 | 40,000 | 5′ |
PH-75 (High output) | 37,000 | 75,000 | 10′ |
Gas Pressure at Manifold: | |
Natural Gas | 3.5″ W.C. |
L.P. Gas | 10.5″ W.C. |
Gas Connection Size | 0.5″ N.P.T. |
Gas Inlet Pressure: | ||
Gas | Minimum | Maximum |
Natural | 4.5″ W.C. | 14.0″ W.C. |
L.P. | 11.5″ W.C. | 14.0″ W.C. |
Electrical Rating:
DSI Ignition
120v, 60 Hz, 1 Amp/ 24 Volt Power Supply
24 volt low voltage On/ Off- Hi/ Lo Control Panel
Standard Equipment:
Burner control housing is preassembled and pre-wired, unit comes complete with industry standard gas, electrical, balanced air rotor, thermal overload protected motor, visual burner inspection sight glass, combustion and air proving safety switch, 3-try spark ignition control, 100% safety shut-off, low voltage control connection, 4″ heat treated aluminized combustion tube, aluminum standard reflector, tube couplers, heat economizer baffle, stainless steel hangers, decorative grille, indicator light, stainless steel burner head construction.
Optional Equipment:
Elbow kit/ 180 degree U-Bend kit for PH75
Stainless Steel Construction